Download Print this page

Kasco xStream 2400SF050 Owner's Manual page 13

Advertisement

into the 120V power supply on the post and ENJOY YOUR
NEW KASCO AERATOR!
4. Test the GFCI with the test button now and every 30
days.
Any unauthorized modiications to this control panel will
void the UL listing and the Kasco warranty.
C-25 Timer Control Instructions
Portable Timer with Ground Fault Interrupter
IMPORTANT
This portable timer is designed for CONTROLLING the
connected equipment only. Unplug timer before servicing
the unit or the equipment it controls. For maximum protec-
tion against electrical shock hazard, perform test procedure
on G.F.C.I. at least once a month. Mount at least 5 ft. from
open water.
G.F.C.I. TEST PROCEDURE
The G.F.C.I. should be checked every month to make sure
that it is operating properly. Just follow the simple instruc-
tions below. It is recommended to maintain a maintenance
diary of your monthly safety check.
1. Push TEST button, RESET button should pop out from
inner surface. This should result in power being OFF at
the outlet protected by the G.F.C.I. Verify by plugging a
test lamp into the outlet. Be sure the timer is in the ON
position.
2. If the G.F.C.I. tests okay, restore power by pushing the
RESET button back in. THE RESET BUTTON MUST BE
PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT
LOCKS AND RE-MAINS DEPRESSED AFTER PRES-
SURE HAS BEEN REMOVED.
DANGER: IF RESET BUTTON DOES NOT POP OUT,
IF TEST LAMP REMAINS LIT WHEN RESET BUTTON
DOES POP OUT, OR IF THE G.F.C.I. FAILS TO RE-
SET PROPERLY, DO NOT USE TIMER! CONTACT A
QUALIFIED SERVICE TECHNICIAN!
Failure to use the C-25 with Kasco Fountains will void the
warranty and cause the Fountain to not be listed to UL and
CSA standards via ETL.
UNDER NO CIRCUMSTANCES SHOULD ANYONE
ENTER THE WATER WHEN A UNIT IS IN OPERA-
TION!
TIMER-OPERATION INSTRUCTIONS
C-25 Control Box will turn the aerator/fountain ON &
OFF with the TIMER. Kasco lights will turn ON with the
PHOTO EYE and OFF with TIMER. C-25 Control Box is
to be used with Kasco Approved Lights ONLY!
See Control panel label for instructions to set the timer
Plug aerator/fountain cord into the RIGHT hand outlet
(labeled UNIT).
Plug transformer light cord into LEFT hand outlet
(labeled LIGHT).