5.11.6

The vacuum is not maintained after the pump is switched off

The gas-ballast control is open.
O-ring(s) are damaged or missing.
The shaft seals have deteriorated.
5.11.7

The pumping speed is poor

The connecting pipelines are too small in diameter.
The connecting pipelines are too long.
The inlet-filter is blocked.
5.11.8

There is an external oil leak

The oil pump shaft seal is worn or damaged.
The oil box gasket has deteriorated.
There is an oil leak from gas-ballast control.
There is an oil-leak from the drain-plug.