X+ direction program limit
1033
:
4 - direction machine limit
1034
:
4 + direction machine limit
1035
:
Z - direction machine limit
1036
:
Z + direction machine limit
1037
:
Y - direction machine limit
1038
:
Y + direction machine limit
1039
:
X - direction machine limit
1040
:
X+ direction machine limit
When controller shows limit alarm. Please check corresponding limit sensor point or parameters.
If hard limit occurs, and the appearance of the sensor point doesn t has any problem, enter the diagnosis
mode and check the state of the input port. If the state is valid, please eliminate in sequence. Disconnect
the input IO cable and check whether the sense disappears. If yes, please check the circuit. If the
problem still exists, the internal optocoupler is broken. Please contact the supplier.
1041
:
Emergency stop
Check Emergency stop button of the handheld box is pushed down or not
External emergency stop 2 input is push down?;check whether IO assignment has conflict or
interference.
Search for corresponding function ports in IO configuration, and then check in input diagnosis.
1042
:
X Sevor driver alarm
1043
:
Y Sevor driver alarm
1044
:
Z Sevor driver alarm
1045
:
4 Sevor driver alarm
Servo alarm; if there is no alarm on servo , parameter P2(axis parameter).001~004 setting and actual
servo alarm level may be reverse. Please modify the parameters.
The corresponding function ports are IN34~37, which can be checked in input diagnosis.
1046
:
Axis's physical line redefine
axis No. setting by parameter P2.45~P2.49 is specified repeatedly
1047
:
spi no to home
1048
:
workpiece no lock
1049
:
safe signal can't detect
1051
:
air no enough