Press the mode switch key [Home] to select home operation;
In [Absolute Position] and [Coordinate System] screen, press [X], [Y], [Z], [A],[ B],[C]respectively to show the value
of corresponding axis position, and then press the [Cancel] key to reset the machine position of current axis, i.e.
current positions are used as machine origin position. After this operation, the system considers it as a home action.
Therefore, when the program is running, the alarm of not home won t occur. If you press by mistake, it will switch
the screen and cancel selection automatically.
Reset relative position manually
Press the mode switch key [Manual] to select manual operation;
In [Relative Position] and [Coordinate System] screen, press [X], [Y], [Z], [A] ,[ B],[C] respectively to show the
value of corresponding axis, and then press the [Cancel] key to reset the relative position of current axis.
Note
The tool also can return to home point according to program instruction, i.e. returning tohome point automatically.
Caution:
General ly, the system should do go home operation after power on. If the power off while the machine is working, the
controller also will return to home point when the power on again. So Return to Z axis firstly for preventing tool and workpiece
from colliding and damaging them
.