Download Print this page

gefran EXP-SFTy Manual page 3

Safe stand-still function

Advertisement

Collegamento
I cavi utilizzati per il collegamento dei morsetti XSC
e XSC1 devono essere protetti contro i possibili
danneggiamenti esterni (cavi armati, canaline),
il rivestimento protettivo deve essere adeguato a
garantire un isolamento per la tensione nominale
di 600V.
XSC Connector (SFTy card)
Terminal / Morsetto
/
5/6

4
X1 Connector (AVy drive)
Terminal / Morsetto

6
80/8
X1 Connector (XVy-EV drive)
Terminal / Morsetto
6
5
0 (NO) , (NC),  (COM)
Connection
XSC
1
2
3
4
5
The cables used to connect terminals XSC and
XSC1 must be protected against the risk of ex-
ternal damage (armoured cables, channels). The
protective coating must guarantee isolation for a
rated voltage of 600V.
Descrizione / Description
#  Feedback safety NC contact
#  feedback safety NC contact
+4V dc signals to safety relais
The safety function is active with "LOW" signal
0V ground to supply safety relais
Descrizione / Description
Controller enable
The safety function is active with "LOW" signal
0V ground
free potential NO contact, drive ready to start
Descrizione / Description
Controller enable
The safety function is active with "LOW" signal
0V ground
free potential contacts, drive ready to start
SFTy card
XSC1
6
Range
0Vac, 5A
0Vac , 5A
8...5Vdc / 7...7mA
Range
5...5Vdc / . ... 7.5mA
50Vac, A
Range
5...5Vdc / . ... 7.5mA
50Vac, A


Advertisement

loading
Need help?

Need help?

Do you have a question about the EXP-SFTy and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Exp-sfty-37Exp-sfty-55Exp-sfty-75Exp-sfty-132