Technical Data

Water softener
Nominal connection width
Connection type
Nominal capacity in accordance
with DIN EN 14743
Peak flow when blending from 20°dH to 8°dH
Nominal flow in accordance with DIN EN 14743
Nominal pressure PN
Operating pressure, min./max.
Pressure drop at nominal flow
Application
Ion exchange material fill quantity
Max. supply of regenerative
Approx. consumption of regenerative per
regeneration
Flushing water consumption per regeneration
at 4 bar, approx.
Max. flushing water flow during regeneration
Regeneration time, approx.
Water temperature, min. – max.
Ambient temperature, min. – max.
Humidity
Mains power
Unit voltage
Power during operation
Max. power during regeneration
Max. fault message output
Protection class
Operating weight if filled to max.
Shipping weight, approx.
Production number AQA perla XL CN
Production number AQA perla XL INT
Type
DN
mol (m³ x°dH)
m³/h
m³/h
bar
bar
bar
Residential units
Persons
l
kg
kg
l
l/h
min
°C
°C
V/Hz
VDC
W
W
VDC / A
kg
kg
PNR
PNR
AQA perla XL
32
(G11/4")
2 x 3,2 (2 x 18)
3,8
1,6
10
2 - 8
1,0
4 - 8
4 - 16
2 x 7
50
0,8
40
170
37
5 - 25
5 - 40
non condensing
230/50-60
24
2,6
40
24/0,5
IP54
102
39
6-500128
6-500129
87
87
EN