FIGURE 4-5
8. Pivot the card latch up and then slide it down until it captures the PCI card
bracket. Tighten the screw to secure the latch (refer to
9. Check the routing of all cables for obstructions and then reinstall the cover.
4.5.3

SCSI Hard Disk Drive and Carrier

The following procedure describes how to remove and replace a SCSI hard disk
drive (HDD) and carrier.
Note – SCSI HDDs are hot-pluggable in integrated-mirroring (IM) configurations.
See "Integrated Mirroring" on page E-2 for more information.
See also "SCSI ID Assignments" on page 4-5.
4.5.3.1

Removing an HDD and Carrier

1. If you are not using an integrated-mirroring configuration, you must power off the
server before removing a HDD; it is not necessary to remove the cover. Power off
the system as described in "Powering Off the Server and Removing the Cover" on
page 4-2.
If you are using an IM configuration, start with Step 2.
2. Squeeze the release latch and carefully swing the arm to the left as far as it will go
(see