Linux Operating System Issues
This section describes known problems and associated workarounds on Sun Fire
X4100 and Sun Fire X4200 servers for RHEL operating system and the SLES.
Hard-Disk Drive Display Omits Disk Listing At
Installation When Multiple SCSI disks Are
Attached to System on RHEL4 U4 (6447738)
The hard-disk drive display omits a disk listing during installation if there are many
SCSI disks attached to a system. Not all disks are available during the installation.
In addition, the disk-drive display lists the wrong drive type after the installation.
Workaround
None. However, to display the omitted hard-disk drive, use one of the following
instructions:
During installation, disconnect all external storage devices except those devices
■
needed for disk initialization.
Perform manual disk-initialization after you reboot the system, when all disks are
■
available.
Duplicate Devices Seen by Linux OS if External
RAID Array Connects to Server Through Ultra320
SCSI (6220406)
If a RAID array is attached to the system using a Sun StorEdge PCI/PCI-X Single
Ultra320 SCSI host bus adapter (Ultra320 SCSI), you might see the following if you
enter the command, fdisk -l, depending on which Linux OS you are using:
Duplicate devices for each logical unit number (LUN) in the array
■
One device for multiple LUNs in the array
■
36
Sun Fire X4100 and Sun Fire X4200 Servers Product Notes • November 2006