Configure Alerts - StarTech.com CONYX ECS0016 Instruction Manual

Enhanced console server
Hide thumbs Also See for CONYX ECS0016:
Table of Contents

Advertisement

SNMP alerts
The Administrator can configure the Simple Network Management Proto-
col (SNMP) agent that resides on the console server, to send Alerts to an
SNMP management application:
Alerts & Logging: SNMP.
1.
Select
2.
Enter the SNMP transport protocol. SNMP is generally a UDPbased
protocol though infrequently it uses TCP instead.
3.
Enter the IP address of the SNMP Manager and the Port to used for
connection.
4.
Select the version being used. The console server SNMP agent
supports SNMP v1, v2 and v3
5.
Enter the Community name for SNMP v1 or 2c
6.
To configure for SNMP v3 you will need to enter an ID and
authentication password and contact information for the local
Administrator (in the Security Name)
7.
Click Apply to activate SNMP
Nagios Alerts
To notify the central Nagios server of Alerts, NSCA must be enabled
under System: Nagios and Nagios must be enabled for each applicable
host or port under Serial & Network: Network Hosts or : Serial Ports

Configure Alerts

The Alerts facility monitors the status of the console server and connect-
ed devices and when an alert event is triggered, an Alert message is then