ECS0016 gateways also support dial-back for additional security. Check
the Enable Dial Back box and enter the phone number to be called to re-
establish an OoB link, once a dial-in connection has been logged.

Using The MetaConnect client

Administrators can use the MetaConnect Java client software to set up
secure OoB dial-in access to remote ECS0016 gateways. OoB access
uses a different path for connecting to the gateway than that which is
used for regular data traffic.
Starting an OoB connection in MetaConnect may be achieved by initiating
a dial up connection, or adding an alternate route to the gateway, while
allowing you to provide your own scripts or commands for starting and
stopping the OoB connection.

Set up Windows XP/ 2003 client

Network Connections in Control Panel and click the New
1.
Open
Connection Wizard.
Connect to the Internet and click Next.
2.
Select
Getting Ready screen select Set up my connection manually
3.
On the
and click Next.
4.
On the Internet Connection screen select
modem and click Next.
5.
Enter a Connection Name (any name you choose) and the dial-up
Phone number that will connect thru to the ECS0016 modem
PPP User name and Password that are set up for the
6.
Enter the
ECS0016, select Next, then Finish.

Set up earlier Windows clients

For Windows® 2000, the PPP client set up procedure is the same as
above, except to access the Dial-Up Networking Folder, click the Start
button, select Settings then click Network and Dial-up Connections
followed by Make New Connection.