StarTech.com CONYX ECS0016 Instruction Manual page 121

Enhanced console server
Hide thumbs Also See for CONYX ECS0016:
Table of Contents

Advertisement

Adding more than one SNMP server
To add more than one SNMP server for alert traps add the first SNMP
server using the Management Console or the command line config tool.
Secondary and any further SNMP servers are added manually using
config.
Log in to the console server's command line shell as root or an admin
user.
To set the Manager Protocol field:
config set config.system.snmp.protocol2=UDP or
config set config.system.snmp.protocol2=TCP
To set the Manager Address field:
config set config.system.snmp.address2=w.x.y.z ..
(replacing w.x.y.z with the IP address or DNS name).
To set the Manager Trap Port field:
config set config.system.snmp.trapport2=162 ..
(replacing 162 with the TCP/UDP port number)
To set the Version field:
config set config.system.snmp.version2=1 or
config set config.system.snmp.version2=2c or
config set config.system.snmp.version2=3
To set the Community field (SNMP version 1 and 2c only):
config set config.system.snmp.community2=yourcommunityname ..
(replacing yourcommunityname with the community name)
To set the Engine ID field (SNMP version 3 only):
config set config.system.snmp.engineid2=800000020109840301 ..
(replacing 800000020109840301 with the engine ID)
Instruction Manual
114

Advertisement

Table of Contents
loading

Table of Contents