Serial Bridging Mode; Syslog - StarTech.com CONYX ECS0016 Instruction Manual

Enhanced console server
Hide thumbs Also See for CONYX ECS0016:
Table of Contents

Advertisement

Data Carrier Detect (DCD) pin on the serial device being raised. When
a connection is detected, the getty program issues a login: prompt, and
then invokes the login program to handle the actual system login.

Serial Bridging Mode

Serial bridging is the encapsulation of serial data into network packets
and the transport of the data over a network. So two ECS0016 gateways
can configured to act as a virtual serial cable over IP network.
One gateway is configured as the server in Console Server mode with
either RFC2217 or RAW enabled on the serial port to be bridged.
For the client gateway, the serial port must be set in Bridging Mode. To
do so:
Select Serial Bridging Mode and specify the IP address of the first
ECS0016 gateway and the TCP port address of the remote serial port (for
RFC2217 bridging this will be 5001 - 5016)
By default the bridging client will use RAW TCP, so you must select
RFC2217 if this is the console server mode you have specified on the
server gateway
You may secure the communications over the local Ethernet by
enabling SSH, however you will need to generate and upload keys
Serially Connected Device
(e.g. Security Appliance)

Syslog

In addition to built-in logging and monitoring (which can be applied to seri-
al attached and network attached management accesses. The ECS0016
Instruction Manual
Local Ethernet LAN
21
ECS0016
COM Port Connected
Control PC

Advertisement

Table of Contents
loading

Table of Contents