3)
Selectiva 2250 / 2300 / 2350: If the device is fused with 32 A, the thermal
rating of the automatic circuit breaker must not exceed 210,000 A²s.
4)
Interface to a 230/400 V and 50 Hz public grid.
5)
For indoor use only, must not be exposed to rain or snow.
6)
At a high ambient temperature, a power reduction may occur (derating).
Device-specific data
Device
Max. AC
current
2250 18kW
15.3 A
2300 18kW
15.6 A
2350 18kW
15.9 A
4250 18kW
30.2 A
4300 18kW
30.7 A
4325 18kW
31 A
Max. AC
Nominal
power
voltage
9690 W
24 V
9890 W
24 V
10,060 W
24 V
18,650 W
48 V
19,500 W
48 V
19,620 W
48 V
Max. char-
Z
max
ging cur-
rent
250 A
None
300 A
None
350 A
None
250 A
93
mOhm
300 A
80
mOhm
325 A
75
mOhm
71