Device-specific data
Device
Max. AC
current
4210 16kW
27.6 A
8120 16kW
23.8 A
8140 16kW
27.5 A
8160 16kW
30.3 A
8180 16kW
30.6 A
8210 16kW
30.9 A
Max. AC
Nominal
power
voltage
15,860 W
48 V
14,830 W
80 V
17,270 W
80 V
18,150 W
80 V
18,260 W
80 V
18,430 W
80 V
Max. char-
Z
max
ging cur-
rent
210 A
120 A
96
mOhm
140 A
82
mOhm
160 A
74
mOhm
180 A
67
mOhm
210 A
67
mOhm
69