Fronius Selectiva 4.0 2100 Operating Instructions Manual page 65

Hide thumbs Also See for Selectiva 4.0 2100:
Table of Contents

Advertisement

2)
Only use a type B residual current circuit breaker for the grid connection
of the device.
If the device is fused with 32 A, the thermal rating of the automatic circuit
breaker must not exceed 82,000 A²s.
The leakage current to ground is less than 3.5 mA.
3)
Interface to a 230/400 V and 50 Hz public grid.
4)
For indoor use only, must not be exposed to rain or snow.
5)
At a high ambient temperature, a power reduction may occur (derating).
Device-specific data
Device
Max. AC cur-
rent
2100 8 kW
6.7 A
2120 8 kW
7.8 A
2140 8 kW
9.0 A
2160 8 kW
10.1 A
2180 8 kW
11.2 A
2200 8 kW
12.3 A
2225 8 kW
13.7 A
4060 8 kW
7.3 A
4075 8 kW
9.0 A
4090 8 kW
10.6 A
4090A 8 kW
10.4 A
4120 8 kW
13.8 A
4120A 8 kW
13.7 A
4140 8 kW
14.4 A
4140A 8 kW
14.3 A
4160 8 kW
14.5 A
4160A 8 kW
14.4 A
4185 8 kW
15.3 A
8040 8 kW
8.2 A
8060 8 kW
12.0 A
8060A 8 kW
11.8 A
8075 8 kW
14.1 A
8075A 8 kW
14.0 A
8090 8 kW
14.2 A
8090A 8 kW
14.1 A
8110 8 kW
15.1 A
Max. AC
Nominal
power
voltage
3860 W
24 V
4590 W
24 V
5350 W
24 V
6090 W
24 V
6860 W
24 V
7610 W
24 V
8560 W
24 V
4610 W
48 V
5710 W
48 V
6820 W
48 V
6810 W
48 V
9050 W
48 V
9040 W
48 V
9340 W
48 V
9280 W
48 V
9390 W
48 V
9370 W
48 V
9950 W
48 V
5000 W
80 V
7440 W
80 V
7440 W
80 V
9110 W
80 V
9110 W
80 V
9210 W
80 V
9190 W
80 V
9740 W
80 V
Max. char-
ging current
100 A
120 A
140 A
160 A
180 A
200 A
225 A
60 A
75 A
90 A
90 A
120 A
120 A
140 A
140 A
160 A
160 A
185 A
40 A
60 A
60 A
75 A
75 A
90 A
90 A
110 A
65