EAS28940
CHECKING THE STARTER MOTOR
OPERATION
1. Check:
2. Starter motor operation
Does not operate → Perform the electric
starting system troubleshooting, starting with
step 4.
M
MMM
M MMM
M
M MMM
M
a. Connect the positive battery terminal "1" and
starter motor lead "2" with a jumper lead "3".
EWA13810
WARNING
• A wire that is used as a jumper lead must
have at least the same capacity of the bat-
tery lead, otherwise the jumper lead may
burn.
• This check is likely to produce sparks,
therefore, make sure no flammable gas or
fluid is in the vicinity.
b. Check the starter motor operation.
L
LLL
L LLL
L
L LLL
L
M MMM
M
M MMM
M
M MMM
M
L LLL
L
L LLL
L
L LLL
L
ELECTRICAL COMPONENTS
EAS28150

CHECKING THE STATOR COIL

1. Disconnect:
• Stator coil coupler
(from the wire harness)
2. Check:
• Stator coil resistance
Out of specification → Replace the crank-
shaft position sensor/stator assembly.
Stator coil resistance
MMM
M
MMM
M MMM
M
a. Connect the pocket tester (Ω × 1) to the stator
coil coupler as shown.
• Positive tester probe →
white "1"
• Negative tester probe →
white "2"
• Positive tester probe →
white "1"
• Negative tester probe →
white "3"
• Positive tester probe →
white "2"
• Negative tester probe →
white "3"
LLL
b. Measure the stator coil resistance.
L
LLL
L LLL
L
EAS28170

CHECKING THE RECTIFIER/REGULATOR

1. Check:
• Charging voltage
Out of specification → Replace the rectifi-
er/regulator.
0.448–0.672 Ω at 20 °C (68 °F)