Operation
A
Selected mode of operation
Right auxiliary port connector
B
Selected flow rate level
C
Left auxiliary port connector
D
After the indication of the flow rates the selected mode of operation
is indicated in the display once more.

Flow rate setting

Suppose the same implement has to be attached to a different excavator. Even when using identical flow rate set-
tings for the other excavator, the working speed may differ. For each excavator, you need to individually adjust the
flow rate settings. Upon changing the implement, you need to determine and adjust the optimum flow rates for the
new implement.
The flow at auxiliary port 1 is not constant when using a different function or if a relief valve is respond-
ing.
It is recommended to adjust this setting during the operation of the implement.
Turn the starter switch to the RUN position.
!
Press menu button (2).
!
The display message as in the figure on the right appears.
!
Press display selector switch (1) until AUX is shown in the dis-
!
play.
To toggle between the operating modes, press and hold the
!
display selector switch (1) again.
Press the display selector switch (1) repeatedly until the de-
!
sired indicator appears in the display.
Press and hold the display selector switch until the selected op-
!
erating mode's flow rate is shown on the display.