Filling Up The Washer System; Refuelling The Excavator - Kubota KX015-4 Operating Instructions Manual

Mini
Table of Contents

Advertisement

Operation

Filling up the washer system

Open the cap (1) of the washer system reservoir (2) and add
!
water or a cleaning agent.
In winter, use a cleaning agent with antifreeze.

Refuelling the excavator

When refuelling the excavator, smoking, an open flame, or other sources of ignition are not allowed.
The danger zone has to be clearly marked with signs. A fire extinguisher must be kept at hand in the
danger zone.
Spilled fuel must be bound immediately with an oil binding agent. The contaminated oil binding agent
must be disposed of in accordance with the applicable environmental regulations.
If no pumping station is available, the diesel fuel may only be stored in approved canisters.
STOP
Refuel the excavator in time so that the fuel tank is not running empty. Air in the fuel system can dam-
age the fuel injection pump.
Stop the engine.
!
Insert the ignition key in the lock (1) of the filler cap (2) and turn
!
it anti-clockwise.
Open the filler cap by turning it anticlockwise.
!
1
2
2
1
103