Power Supply and Ground

2-3
Power Supply and Ground
Wire the power supply and the ground to the top terminal block,
and tighten the screws to a torque of between 0.5 and 0.6 N m.
After wiring, check to make sure that the wiring is correct.
!
WARNING
Cover the terminal blocks with the Terminal Block Protection
Covers. Uncovered terminal blocks can result in electric shock.
2-3-1
Crimp Terminals and Cables
The terminal block uses M3 terminal screws. Use appropriate
crimp terminals for M3 screws, as shown below.
Forked
6.2 mm max.
Applicable wire size: Insulated wire, 1.31 to 1.65 mm
to AWG15)
2-3-2
Protective Conductor (Earth) Wiring
Ground of 100 Ω or
less.
Note
10
1. Use an appropriate ground. An insufficient ground can af-
fect V530-R150 operation or result in damage to
V530-R150 components.
2. To avoid damage to the equipment, do not share the protec-
tive conductor wiring with any other devices nor wire the
protective conductor terminal to the girder. Be sure to wire
the protective conductor of the equipment independently.
3. Keep the ground line as short as possible.