Crimp Terminals and Cables
The terminal block uses M3 terminal screws. Use appropriate
crimp terminals for M3 screws, as shown below. Tighten the
screws to a torque of between 0.5 and 0.6 N m. After wiring,
check to make sure that the wiring is correct.
!
WARNING
Cover the terminal blocks with the Terminal Block Protection
Covers. Uncovered terminal blocks can result in electric shock.
Forked
6.2 mm max.
Applicable wire size: Insulated wire, 1.31 to 1.65 mm
to AWG15)
3-1-2
Specifications
WARNING
!
Use a DC power supply with safe extra low-voltage circuits on
the secondary side. Excessively high voltage can result in
electric shock.
Input Specifications
Item
Input voltage
12 to 24 VDC 10%
ON current
3 to 15 mA
ON voltage
8.8 V max.
OFF current
0.1 mA max.
OFF voltage
4.5 V min.
ON delay
RESET input: 10 ms max.
Others:
OFF delay
RESET input: 15 ms max.
Others:
Internal circuits