Trigger Input And Output Format - Omron V530-R150 Operation Manual

2-dimensional code reader
Hide thumbs Also See for V530-R150:
Table of Contents

Advertisement

Trigger Input and Output Format

3-2
Trigger Input and Output Format
3-2-1
Trigger Input
Reading is performed by inputting a signal to the TRIG A or B ter-
minals when in MON (monitor) or RUN mode.
TRIG A Terminal (One shot mode)
One reading is performed on the rising edge (OFF to ON) of
TRIG A signal.
Correct Reading: Reading ends, then reading judgment is out-
put.
Incorrect Reading: Reading continues to be performed for the
number of retries specified in the setting conditions.
As the TRIG A signal is synchronous with the shutter input of the
Camera, an accurate image of the moving object can be ob-
tained.
TRIG B Terminal (Continuous mode / Level trigger mode)
Changed by setting of communications specifications.
Trigger Mode
Continuous mode (Default
setting)
Level trigger mode
3-2-2
Output Format
Signals are output in RUN mode but not in MON (monitor) mode.
OK/NG Terminal
Output OK/NG judgment.
Judgment
OK
NG
OK: ON or NG: ON (i.e.: whether output turns ON for an OK judg-
ment or an NG judgment) can be selected in the communications
How to set the number of retries.
p. 143
Performs continuous reading while the TRIG B terminal is
ON.
Repeats reading while the TRIG B terminal is ON until
reading judgement is OK (readable).
OK when 2-dimensional codes are read successfully.
The reading data will be output to RS-232C.
NG when 2-dimensional codes are not read successfully.
The error code will be output to RS-232C.
NG when coincidence judgment is set to ON and the
reading data is not coincident with the registered data 0 to
3.
The reading data will be output to RS-232C.
Section
p. 97, 113
Detail
Detail
3-2
25

Advertisement

Table of Contents
loading

Table of Contents