50 Disassembly and assembly
42. Belt tensioner
Install belt tensioner (2) with mounting bolt (1).
43. Idler roller and hanging plate
1)
Install hanging plate (1) with bolt (2).
Install only 1 bolt.
q
2)
Install idler roller (3) with bolt (4).
Clamp the hanging plate, too.
q
44. Vibration damper
1)
Install vibration damper (4).
3
Mounting bolt:
114E-3 Series
200 ± 10 Nm {20 ± 1.0 kgm}
2)
Install pulley (3).
45. Fan belt and wiring harness
1)
Install fan belt (1).
Insert a wrench to the portion (A) (width
q
across flats T 12.7 mm) of the tensioner
assembly (2), and rotate it to the opposite
to the winding-up direction to decrease the
fan belt (1) tension.
k
Make sure that the wrench is
secured at the portion (A) before
rotating it. (The spring of the ten-
sioner assembly (2) is strong. If the
wrench is loosely inserted, the
wrench may accidentally come off
w h i l e b e i n g r o ta t e d a n d i t i s
extremely dangerous.)
k
Install the fan belt (1), return the
tensioner assembly (2) slowly with
care.
k
Be careful not to get your fingers
caught between the pulley and fan
belt (1) during work.
2)
Install wiring harness (3).
a Check that the clearance between
wiring harness (3) and fan belt (1) is
15 mm or wider.
SEN00464-01
31