Code [222/Ca222] Ambient Air Press. Sensor Low Error - Komatsu 114E-3 Series Shop Manual

Table of Contents

Advertisement

SEN00459-01
E-14 Code [222/CA222] Ambient Air Press. Sensor Low Error
Error code
Failure code
222
Contents of
• Low voltage is detected in atmospheric pressure sensor
trouble
Action of con-
• Fixes atmospheric pressure and continues operation.
troller
Problem that
• Engine output drops.
appears on
• Starting performance is poor.
machine
Related infor-
• Method of reproducing failure code: Starting switch ON.
mation
Defective sensor power sup-
1
ply 1 system
Defective atmospheric pres-
2
sure sensor
Ground fault in wiring har-
3
ness (Short circuit with GND
circuit)
Possible causes
and standard
value in normal
state
Short circuit in wiring har-
4
ness (With another wiring
harness)
Defective wiring harness
5
connector
6 Defective engine controller
26
Trouble
CA222
Causes
Abnormally low level in atompspheric pressure sensor
Standard value in normal state/Remarks on troubleshooting
If failure code [CA352] is indicated simultaneously, carry out trouble-
shooting for it first.
a Prepare with starting switch OFF, then turn starting switch ON
and carry out troubleshooting.
AMBAIR PRESSURE
Between (1) – (2)
Voltage is measured with wiring harness connected. Accordingly, if
voltage is abnormal, check wiring harness and controller, too, for
another cause of trouble, and then judge.
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Wiring harness between J1 (female) (3) –
AMBAIR PRESSURE (female) (3)
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Wiring harness between J1 (female) (3) –
AMBAIR PRESSURE (female) (3) and J1
(female) (38) – AMBAIR PRESSURE
(female) (2)
Connecting parts among atmospheric pressure sensor, engine wir-
ing harness, and engine controller are suspected. Inspect them
directly.
• Loose connector, broken lock, broken seal
• Corrosive, bent, broken, forced-in, or extended pin
• Humidity in connector, entry of dirt or dust, poor insulation
a Prepare with starting switch OFF, then turn starting switch ON
and carry out troubleshooting.
J1
Between (33) – (38)
40 Troubleshooting
Power supply
4.75 – 5.25 V
Resis-
tance
Resis-
tance
Power supply
4.75 – 5.25 V
114E-3 Series
1
Voltage
Min.
100 kz
Min.
100 kz
Voltage

Hide quick links: