Komatsu 114E-3 Series Shop Manual page 325

Table of Contents

Advertisement

50 Disassembly and assembly
2)
Tightening order of bolts
1]
Install lock plate (1).
2]
Tighten the bolts in the numerical
order shown below: [1]
3
Mounting bolt:
137 ± 7 Nm {14.0 ± 0.7 kgm}
3)
After installing the flywheel, measure the
radial runout and facial runout with tool L.
a Radial runout: Max. 0.13 mm
a Facial runout: Max. 0.20 mm
Measuring radial runout
q
1)
Install tool L to the flywheel housing.
2)
Set the probe of the dial gauge per-
pendicular to spigot joint portion (a) or
periphery of the flywheel.
3)
Rotate the flywheel by 1 turn and
measure the difference between the
indicated lowest and highest values.
a After the flywheel is rotated by 1 turn,
check that the dial gauge indicates
the value at the start of rotation.
Measuring facial runout
q
1)
Similarly to measurement of the radial
runout, set the probe of the dial
gauge perpendicular to end face (b)
of the flywheel near the periphery.
a When
crankshaft to the front or rear
side so that an error will not be
caused by the end play.
2) Rotate the flywheel by 1 turn, and mea-
sure the difference between the indi-
cated lowest and highest values.
114E-3 Series
[8]
measuring,
bring
the
19. Starting motor assembly
1)
Apply string (A) of gasket sealant 1 mm in
diameter.
2
Both sides of gasket:
2)
Fit the gasket and install starting motor
assembly (1) and spacer (2) with bolt (3)
and nut (4).
SEN00464-01
Gasket sealant (LG-7)
17