Komatsu 114E-3 Series Shop Manual page 219

Table of Contents

Advertisement

40 Troubleshooting
Possible
causes and
standard value
9 Defective engine controller
in normal state
Circuit diagram related to engine controller power supply
114E-3 Series
Causes
a Prepare with starting switch OFF, then turn starting switch ON and
START and carry out troubleshooting.
Between (3) – (1)
Standard value in normal state/Remarks on troubleshooting
J3 (Female)
Starting switch
SEN00460-01
Voltage
ON
Min. 24 V
START
Min. 12 V
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Saa6d114e-3

Table of Contents

Save PDF