DVS Fast Charging System
Cod
Fault Messages
e
126
Temp Sensor Failure
128
Internal Failure
129
Power Imbalance
132
Invalid Pilot on Port A
133
Chrg Vdc Port A Low
134
Chrg Vdc Port A High
135
BMID A Vbat Too Low
136
BMID A Vbat Too High
137
Tbat Too High on Port
A
138
BMID Comm Fail Port
A
139
BMID Config Warning
on Port A
140
BMID Config Mismatch
on Port A
141
BMID Failure on Port A BMID reporting a critical failure
142
BMID Temp Sensor
Failure on Port A
143
Vbat Mismatch on Port
A
144
Battery
Overdischarged on
Port A
145
Early Charge
Termination on Port A
164
Invalid Pilot on Port B
165
Chrg Vdc Port B Low
166
Chrg Vdc Port B High
167
BMID B Vbat Too Low
168
BMID B Vbat Too High
23411-W-03-01
Description
Invalid temperature sensor reading
Power Supply Internal Hardware
Failure
Power Stage power imbalance in
500A mode
Battery connected with invalid pilot
circuit
Battery voltage too low for charger
Battery voltage too high for charger
Battery voltage too low for BMID
Battery voltage too high for BMID
Battery temp too high
BMID link lost after charge started
BMID not adequately configured for
charger usage
BMID data doesn't match battery
parameters
BMID temp sensor out of valid range
BMID and terminal voltages don't
match
Battery excessively discharged
Charge terminated unexpectedly
Battery connected with invalid pilot
circuit
Battery voltage too low for charger
Battery voltage too high for charger
Battery voltage too low for BMID
Battery voltage too high for BMID
Page 23 of 29
Action
NN
B
JJ
MM
Z
Z
L
L
H
F
M
J
G
G
KK
K
BB
MM
Z
Z
L
L
Webasto Charging Systems, Inc.

Hide quick links:

Advertisement