DVS Fast Charging System
Cod
Fault Messages
e
169
Tbat Too High on Port
B
170
BMID Comm Fail Port
B
171
BMID Config Warning
on Port B
172
BMID Config Mismatch
on Port B
173
BMID Failure on Port B BMID reporting a critical failure
174
BMID Temp Sensor
Failure on Port B
175
Vbat Mismatch on Port
B
176
Battery
Overdischarged on
Port B
177
Early Charge
Termination on Port B
23411-W-03-01
Description
Battery temp too high
BMID link lost after charge started
BMID not adequately configured for
charger usage
BMID data doesn't match battery
parameters
BMID temp sensor out of valid range
BMID and terminal voltages don't
match
Battery excessively discharged
Charge terminated unexpectedly