10. OPTIONS AND AUXILIARY EQUIPMENT
10.2.2 External dynamic brake (400V class)
(1) Selection of dynamic brake
The dynamic brake is designed to bring the servo motor to a sudden stop when a power failure occurs
or the protective circuit is activated.
The corresponding parameter value must be set to use the external dynamic brake. For parameter
settings, refer to the External dynamic brake section of the corresponding Servo Amplifier Instruction
Manual since they are the same as those of the 11k to 22kW servo amplifiers.
MR-JS-30KA4/B4 MR-H30KAN4/BN4
MR-JS-37KA4/B4 MR-H37KAN4/BN4
MR-JS-45KA4/B4 MR-H45KAN4/BN4
MR-JS-55KA4/B4 MR-H55KAN4/BN4
(2) Connection example
Use the following wires to connect the dynamic brake.
Dynamic
Brake
DBU-55K-4
Downloaded from
ManualsNet.com
POINT
Configure up a sequence which switches off the contact of the brake unit
after (or as soon as) it has turned off the servo on (son) at a power failure
or failure.
For the braking time taken when the dynamic brake is operated, refer to
Section 9.3.
The brake unit is rated for a short duration. Do not use it for high duty.
The specifications of the input power supply for external dynamic brake
are the same as those of the converter unit control circuit power supply.
Servo Amplifier
2
Wire[mm
]
a b
U V W
2
14
search engine
Converter unit
MR-HP55KA4
10 - 15
Dynamic Brake
DBU-55K-4