6. INSPECTION

6. INSPECTION
WARNING
6.1 Inspection
It is recommended to make the following checks periodically:
1) Check for loose terminal block screws. Retighten any loose screws.
2) Check the servo motor bearings, brake section, etc. for unusual noise.
3) Check the cables and the like for scratches and cracks. Perform periodic inspection according to
operating conditions.
4) Check the servo motor shaft and coupling for misalignment.

6.2 Life

The following parts must be changed periodically as listed below. If any part is found faulty, it must be
changed immediately even when it has not yet reached the end of its life, which depends on the operating
method and environmental conditions.
For parts replacement, please contact your sales representative.
Part Name
Smoothing capacitor
Cooling fan
Downloaded from
ManualsNet.com
Before starting maintenance and/or inspection, make sure that the charge lamp is
off more than 20 minutes after power-off. Then, confirm that the voltage is safe in
the tester or the like. Otherwise, you may get an electric shock.
Any person who is involved in inspection should be fully competent to do the work.
Otherwise, you may get an electric shock. For repair and parts replacement,
contact your safes representative.
POINT
Do not test the servo amplifier with a megger (measure insulation resistance),
or it may become faulty.
Do not disassemble and/or repair the equipment on customer side.
Life Guideline
10 years
10,000 to 30,000