Technical specifications

VPB S300
Volume
Volume, charge coil
Heat transfer (60/50°C at 50°C hot water temperature)
Heat content at 50 °C
Equivalent amount of hot water (40 °C)
Heating time (12 °C to 62 °C)
Primary coil capacity, domestic water (80 °C to 40 °C)
Max operating temperature
Max pressure, primary side
Max pressure, water heater
Max water supply pressure
Pressure reduction valve, setting
Max design pressure
Exp. vessle, tap water, charge pressure
Expansion relief valve, setting
Max temperature, heating fluid
Max operating pressure of T&P-valve
Max operating temperature T&P-valve
Height
3
Required ceiling height
Width
Depth
Net weight
Gross weight
Part No.
1
At incoming temperatures 10 °C and hot water draining of 30 l/min.
2
At primary flow temperature 80 °C and primary flow 1025 l/h.
3
With the feet removed, the required ceiling height is approx. 1930 mm.
Tested according to standard EN 12897:2016.
26
Chapter 4 | Technical data
1
2
litre
litre
kW
kWh
litre
minutes
litre
°C
bar/MPa
bar/MPa
bar/MPa
bar/MPa
bar/MPa
bar/MPa
bar/MPa
°C
bar/MPa
°C
mm
mm
mm
mm
kg
kg
Stainless
276
8.8
13.1
13.4
455
27
268
85
3/0.3
6/0.6
16/1.6
3.5/0.35
6 / 0.6
3.5/0.35
6/0.6
85
7/0.7
95
1800
1950
600
626
125
410
081 147
NIBE VPB S/ VPBS S