Technical specifications

Model
1
Efficiency class
Heating medium circuit
Volume coil
The coil's heat transfer surface
Max. working pressure in tank
Max. working pressure in hot water coil
Corrosion protection, hot water coil
Max. operating temperature
Max. heat pump output
Tap volume 40 °C
Pipe connections
Cold water
Hot water
Heat pump supply line
Heat pump return line
Drain heating medium
Venting
Dimensions and weight
Diameter Ø (incl. insulation)
Height
Required ceiling height
Net weight
Substances according to Directive (EG) no. 1907/2006, article 33 (Reach)
Part No.
1
Scale for the product's efficiency class A+ to F.

Energy labelling

Supplier
Model
Energy efficiency class
Heat loss
Volume
NIBE VPC 500/750
VPC 500
C
W
91
l
475
VPC 500
C
litre
35
2
m
Bar/MPa
3 / 0.3
Bar/MPa
6 / 0.6
Stainless steel
°C
kW
litre
See diagram
G1¼" ext. thread
G1¼" ext. thread
G1½" int. thread
G1½" int. thread
G1" ext. thread
G1" ext. thread
mm
760
mm
1,973
mm
2,002
kg
134
Lead in brass components
081 066
NIBE
VPC 750
Chapter 4 | Technical data
VPC 750
-
35
8.5
90
40
910
2,032
2,076
165
081 067
-
114
772
13