CONNECTING COLD AND HOT WATER
The settings for hot water are made in the compatible
product's menu system.
Stop temperature for hot water must be at least 60°C.
Install as follows:
• controlling hot water sensor (BT6) (placed in the
middle of the water heater)
• shut-off valve
• non-return valve
• expansion relief valve
The expansion relief valve must have a maximum 0.6
MPa (6.0 bar) opening pressure and be installed on
the incoming domestic water line as shown.
• mixing valve
A mixing valve must be installed when the factory
setting for hot water is changed. National regulations
must be observed.
• pressure relief valve
• expansion vessel
The expansion vessel (CM4) accomodates expansion
that results from heating the water inside the unit.
The expansion vessel must be connected between
the expansion releif valve (FL1) and the water heater.
The location of the expansion vessel should allow ac-
cess to recharge the pressure as and when nec-
cessary.
• tundish
XL4
INSTALLATION ALTERNATIVE
NOTE
This is the outline diagram. Actual installations
must be planned according to applicable
standards.
VPB S/ VPBS S can be installed in several different ways,
some of which are shown here.
18
Chapter 3 | For the Installer
XL3
Further option information is available at
and in the respective assembly instructions for the heat
sources used.
To external heat source
VPBS S300 can be docked to an external heat source,
e.g. a stove with a back boiler or a thermal solar install-
ation.
Install as follows:
• sensor for external heat source, tank (BT54)
• solenoid valve (FL7).
• pressure gauge
• expansion vessel
• pressure relief valve
• AXC module
• circulation pump
• sensor, external heat source (BT53)