Connection Of Hemisphere V200S Gps Compass - Koden CVS-872D Installation Manual

Color echo sounder
Table of Contents

Advertisement

CVS-872D

1.5.3 Connection of Hemisphere V200s GPS Compass

Connect CW-376-5M by soldering with the cable of Hemisphere V200s GPS Compass.
Please prepare two CW-376-5M when connecting with Radar as GPS compass.
1) The terminal of the cables of V200s GPS Compass is not processed, and 8 lead wires and
1 shield wire are open. Brown and blue lead wires are connected to TX/RX of Port A, white
and green lead wires are connected to TX/RX of Port B, black and red lead wires are
connected to +/- of power supply, and yellow lead wire is connected with earth. Violet and
gray lead wire are unconnected.
Refer to the "Connection table of V200s GPS Compass", and solder CW-376-5M with
Port A and power supply of cable of Hemisphere V200s GPS Compass. Please solder
another CW-376-5M with Port B, when connecting with Radar as GPS compass. Please
branch yellow wire (GND) of the cable of V200s GPS Compass into four, two of which shall
be soldered with each black (RX-) and red (TX-) of CW-376-5M. After soldering is
completed, be sure to process the connected part by self-adhesive tape etc. to be water
resistant and insulated.
CW-376-5M
To J3 connector of
CVS-872D
CW-376-5M
To NMEA terminal of Radar
0092607062-01
Blue and shield
White
Orange
Green
Red
Black
Yellow wire is branched into 4.
Port C
Red
Black
White
Orange
Unconnected
Fig. 1.57 Connection of V200s GPS Compass
Chapter 1 Installation
Black
Port A/Power
Brown
Blue
Red
Yellow
Yellow
Yellow
Yellow
Cable of V200s GPS Compass
Green
White
Violet
Gray
1-63