Renishaw ATOM Installation Manual page 66

Linear encoder system
Hide thumbs Also See for ATOM:
Table of Contents

Advertisement

Output signals
Digital
Function
Signal
Power
1
5 V
0 V
Incremental
+
A
+
B
Reference mark
+
Z
Alarm
2
+
E
Set-up
X
Shield
-
Do not connect
-
1
All power connections should be used either to minimise voltage drop down the cable or incorporate voltage sensing.
2
The alarm signal can be output as a line driven signal or 3-state. Select the preferred option at time of ordering.
66
ATOM linear encoder system
Pin
7, 8
2, 9
14
6
13
5
12
4
11
3
1
Case
10, 15
Analogue
Function
Signal
Power
1
5 V
0 V
+
Cosine
V
1
Incremental
+
Sine
V
2
Reference mark
+
V
0
Set-up
V
X
Remote CAL
CAL
Shield
-
Do not connect
-
Analogue speed
20 µm system - 10 m/s (−3dB)
40 µm system - 20 m/s (−3dB)
Pin
4, 5
12, 13
9
1
10
2
3
11
6
14
Case
7, 8, 15

Advertisement

Table of Contents
loading

Table of Contents