Renishaw ATOM Installation Manual page 28

Linear encoder system
Hide thumbs Also See for ATOM:
Table of Contents

Advertisement

Approved ESD precautions must be followed at all times during readhead electrical connection.
Removing the FPC cable
1. Placing your finger on the whole of the locking lever, slowly lift it up and away to disengage the locking mechanism.
2. Ensure locking lever is fully open before removing the FPC cable.
3. Pull the FPC cable straight back to remove it.
28
ATOM linear encoder system
CAUTION: Do not use tools such as screwdrivers or tweezers to open the
locking lever as this may cause damage to the connector or PCB.
CAUTION: Do not pull upwards or sideways as this may damage the readhead.

Advertisement