Renishaw ATOM Installation Manual page 26

Linear encoder system
Hide thumbs Also See for ATOM:
Table of Contents

Advertisement

For FPC variants
Ensure that the FPC cable being used has the following specifications:
16 core
Conductor pitch 0.5 mm
Minimum exposed conductor strip length 1.5 mm
Maximum exposed conductor strip length 2.5 mm (to ensure isolation from the body)
Contact your local Renishaw representative for more information regarding FPC design requirements.
Shielding
For optimum performance:
Ensure 100% shielding
Ground the mounting brackets
Ensure continuity of all shields
Maximise the distance between the encoder and motor cables
Provide appropriate strain relief at the readhead
26
ATOM linear encoder system
Example of strain relief
4 mm
Shield
connect pad
Readhead LED
0-0.5 mm
3.25 mm
FPC connector
PCB
FPC cable