3.3 Selecting Clock Supply

There are two ways to supply a clock to the MCU, using the oscillator circuit of the emulation pod
or using the oscillator circuit on the target system. Table 3.2 lists the factory-settings of each clock
supply.
Table 3.2 Clock supply to the MCU
Clock
X
IN
X
CIN
Notes on Changing the Clock Supply:
Description
Internal oscillator circuit of emulation pod
(OSC-3: 10MHz)
-X
OUT
Target System
Internal oscillator circuit of emulation pod
(OSC-2: 32.768kHz)
-X
COUT
Target System
• The clock supply can be set by the Init dialog when starting up the emulator debugger
or inputting CLK command on the script window.
• For X
-X
CIN
COUT
refer to "3.2 Switch Settings" (page 25).
Display of emulator debugger Default setting
IMPORTANT
pins, it is necessary to set switches in the emulation pod. For details,
( 29 / 72 )
Internal
External
Internal
External
O
-
O
-