Section 2 Software Specifications when Using the SH7362
2.1
Differences between the SH7362 and the Emulator
1. When the emulator system is initiated, it initializes the general registers and part of the control
registers as shown in table 2.1. The initial values of the actual SH7362 registers are undefined.
When the emulator is initiated from the workspace, a value to be entered is saved in a session.
Table 2.1 Register Initial Values at Emulator Link Up
Register
R0 to R14
R15 (SP)
R0_BANK to R7_BANK
PC
SR
GBR
VBR
MACH
MACL
PR
SPC
SSR
RS
RE
MOD
A0G, A1G
A0, A1
X0, X1
Y0, Y1
M0, M1
DSR
2. The emulator uses the H-UDI; do not access the H-UDI.
Emulator at Link Up
H'00000000
H'A0000000
H'00000000
H'A0000000
H'700000F0
H'00000000
H'00000000
H'00000000
H'00000000
H'00000000
H'00000000
H'000000F0
H'00000000
H'00000000
H'00000000
H'00000000
H'00000000
H'00000000
H'00000000
H'00000000
H'00000000
15