Installation; Z-Wave Configuration Settings - Philio PAT15 Quick Start Manual

Flood water sensor
Table of Contents

Advertisement

Installation

1. To mount the device on the wall, you can choose using the tape, or
the screw.
2. Using the screw to fix the flood detector.
Warning:
1. Before the product is installed, please make sure the surface is clean.
Especially for the surface of glass and wood, keep it dry before
installation.
2. It is highly recommended to press the product on double-sided tape
for 30 seconds.

Z-Wave Configuration Settings

Notice:
* All of the configuration, the data size is 1.
*All of the configuration after the remove the setting still keep, don't
reset to factory default. Unless the user execute the "RESET"
procedure.
* The reserve bit or not supported bit is allowed any value, but no
effect.
NO.
Name
Def. Valid
Auto Report
1
60
Tick Interval
Auto Report
2
6
Battery Time
3
Customer
13
Function
1
0
1
1
0
6
Description
1 ~
The interval time for auto report
0xFF
each tick.(unit:minute)
1 ~
The interval time for auto report the
0xFF
battery level.
Operation mode. Using bit to
All
control.
Bit0: Disable auto report battery
function.
0 : Disable / 1 : Enable
Bit1: Reserve.
Bit2: Disable auto report flood
function.
0 : Disable / 1 : Enable
Bit3: Turn off the beep sound.
0 : Disable the beep sound.
1 : Enable the beep sound.
Bit4: Reverse flood signal.
1 : Reverse Mode, Short → Not
trigger, Open → Trigger.
0 : Normal Mode, Short → Trigger,