Agilent Technologies E2730A Installation And Operation Manual page 15

Vxi rf tuner
Table of Contents

Advertisement

10 MHz
EXT REF
1-2
contains a microminiature D-type connector (AUX) which provides the
RS-232 interface port (for externally controlling the unit). The VXI P1
and P2 multipin connectors for the VXI interface are mounted on the rear
panel of the unit. Refer to Section 2 for further details on the unit's
input/outputs.
Two LEDs (ERR and RUN) on the E2730A front panel monitors tuner
operations and provide indications for operator information and control.
Refer to Section 3 for more information on these indicators.
The E2730A tuner contains seven modules. Six of the modules are PC
boards which contain surface-mounted components and plug-in, metal-
cased components. The seventh module is a plug-in YIG Assembly. The
modules are attached to a milled-out aluminum housing that makes up the
main chassis.
Agilent
E2730A
VXI RF TUNER
Manufacturer Code - OxFFF Hex
Model Code - 2B6 Hex
Message/Register Based Servant
A16 D16/D32 Slave
POWER REQUIREMENTS
DC Voltage
+5V
-5.2V
-2V
+12V
-12V
DC Current
2.2A
0.40A
0.03A
0.86A
0.11A
0.05A
Dynamic Current
0.05A
0.05A
0
0.15A
0.10A
0.05A
ISM 1-A
Figure 1-1. E2730A VXI RF Tuner
Cooling (14 deg C rise)
+24V
-24V
+ 6 V Stdby
3.0 liters/sec
0
.15 mm H
0
2
0
GENERAL DESCRIPTION
E2730A VXI RF TUNER
ATTENTION:
o Front Panel fasteners must be secured
to insure proper operation
CAUTION:
o Use clean handling techniques.
o Install only with metal covers attached.
WARNING:
o Turn off power to instruments and field
wiring before installing or removing any
module.
o Regard all connectors as being at the
same potential as the highest voltage
applied to any connector.
99-0086