Transsteel 5000 Pulse Mv Nc - Fronius TransSteel 4000 Pulse Operating Instructions Manual

Mig/mag power source
Hide thumbs Also See for TransSteel 4000 Pulse:
Table of Contents

Advertisement

TransSteel 5000
Grid voltage (U
Pulse MV nc
Max. effective primary current (I
3 x 200 V
3 x 230 V
3 x 400 V
3 x 460 V
Max. primary current (I
3 x 200 V
3 x 230 V
3 x 400 V
3 x 460 V
Mains fuse protection
3 x 200 V / 230 V
3 x 400 V / 460 V
Mains voltage tolerance
Grid frequency
cos phi (1)
Max. permitted grid impedance Z
PCC
Recommended residual-current circuit
breaker
Welding current range (I
MIG/MAG
MMA
Welding current at 10 min / 40 °C (104 °F)
U
U
Output voltage range according to stan-
dard characteristic (U
MIG/MAG
MMA
Open circuit voltage (U
Apparent power
at 200 V AC / 500 A / 40% D.C.
at 400 V AC / 500 A / 40% D.C.
Protection class
Type of cooling
Insulation class
Overvoltage category
Pollution degree according to IEC60664
Safety markings
Dimensions l x w x h
)
1
1max
1)
)
2
200 V
1
208 - 460 V
1
)
2
peak / U
0
)
1eff
)
on
max
r.m.s)
0
2)
2)
747 x 300 x 497 mm / 29.4 x 11.8 x 19.6 in.
3 x 200 V / 230 V / 400 V / 460 V
63 A slow-blow
35 A slow-blow
-10 / +15%
50 / 60 Hz
52.2 mOhm
10 - 500 A
10 - 500 A
35% / 500 A
60% / 420 A
100% / 360 A
40% / 500 A
60% / 420 A
100% / 360 A
14.3 - 39 V
20.2 - 40 V
23.08 kVA
22.49 kVA
S, CE, CSA
39.5 A
36.3 A
20.6 A
18.1 A
66.7 A
57.4 A
32.5 A
28.6 A
0.99
Type B
57 V
IP 23
AF
B
III
3
115

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Transsteel 5000 pulse

Table of Contents