Installation; Checklist For Installation; Protective Circuit - Fronius TS 65A-3 Operating Instructions Manual

Smart meter
Hide thumbs Also See for TS 65A-3:
Table of Contents

Advertisement

Installation

Checklist for in-
For installation information, see the following chapters:
stallation
1
2
3
4
5
6
7
8
9
10
11
12
Installation
Protective cir-
The Fronius Smart Meter TS is a hard-wired device and requires a disconnecting
cuit
device (circuit breaker, switch or disconnector) and overcurrent‑protection (auto-
matic‑circuit breaker).
Switch off the power supply before establishing a mains connection.
Mount the Fronius Smart Meter TS (see "Installation" on page 17).
Connect automatic circuit breakers or automatic circuit breakers and discon-
nectors
(see"Protective
Connect the mains cable to the Fronius Smart Meter TS (see "Cabling" on
page 18).
Fit the protective cover for the terminals (see
for the
terminals" on page 19).
Connect the data communication connections of the Fronius Smart Meter
TS to the Fronius system monitoring using a suitable cable (see
the data communication cable to the
If necessary, set terminating resistors (see
istor" on page 21).
Tug on each wire and plug to make sure that they are securely connected to
the terminal blocks.
Switch on the power supply to the Fronius Smart Meter TS.
Check the firmware version of the Fronius system monitoring. To ensure
compatibility between the inverter and the Fronius Smart Meter TS, the soft-
ware must always be kept up to date. The update can be started via the in-
verter web page or using Solar.web.
If several Fronius Smart Meter TS are installed in the system, set the address
(see "Setting the address" under
Meter
TS" on page 31).
Configure and commission the meter (see
circuit" on page 17).
"Fitting the protective cover
inverter" on page 19).
"Connecting the terminating res-
"Setting the address on the Fronius Smart
Start-up
The Fronius Smart Meter TS can be
mounted on a 35 mm DIN rail. The
housing comprises 3 modules accord-
ing to DIN 43880.
"Connecting
on page 33).
17