Fronius Smart Meter TS 5kA-3 Operating Instructions Manual

Fronius Smart Meter TS 5kA-3 Operating Instructions Manual

Pv system monitoring

Advertisement

/ Perfect Charging / Perfect Welding / Solar Energy
LEARN MORE WITH
OUR HOW-TO VIDEOS
www.youtube.com/FroniusSolar
Fronius Smart Meter TS 5kA-3
42,0426,0348,EN 005-28072020
Fronius prints on elemental chlorine free paper (ECF) sourced from certified sustainable forests (FSC).
Operating instructions
PV system monitoring

Advertisement

Table of Contents
loading

Summary of Contents for Fronius Smart Meter TS 5kA-3

  • Page 1 / Perfect Charging / Perfect Welding / Solar Energy LEARN MORE WITH OUR HOW-TO VIDEOS www.youtube.com/FroniusSolar Operating instructions Fronius Smart Meter TS 5kA-3 PV system monitoring 42,0426,0348,EN 005-28072020 Fronius prints on elemental chlorine free paper (ECF) sourced from certified sustainable forests (FSC).
  • Page 3: Table Of Contents

    Setting the address on the Fronius Smart Meter TS Start-up Fronius SnapINverter General Connecting to the Fronius Datamanager Configuring the Fronius Smart Meter TS as the primary meter Configuring the Fronius Smart Meter TS as a secondary meter Fronius GEN24 inverter General Installation using the web browser...
  • Page 5: Safety Rules

    Safety rules...
  • Page 7: Safety Rules

    Safety rules General The device has been manufactured in line with the state of the art and according to recognized safety standards. If used incorrectly or misused, however, it can cause: Injury or death to the operator or a third party Damage to the device and other material assets belonging to the operating com- pany.
  • Page 8: Copyright

    The manufacturer accepts no liability for any deleted personal settings. Intended use The Fronius Smart Meter TS is a fixed piece of equipment for public grids of TN/TT sys- tems and records self-consumption and/or individual loads in the system. The Fronius Smart Meter TS is required for systems with a battery storage system and/or a Fronius Ohmpilot installed for communication between the individual components.
  • Page 9 Markings: The devices comply with all the requisite and relevant standards and guidelines that form part of the relevant EU Directive, and are therefore permit- ted to display the CE mark. Insulated (protection class II) Regulatory Compliance Mark (RCM) Complies with all applicable regulatory requirements in Australia and New Zea- land regarding safety and electromagnetic compatibility, as well as specific requirements for radio equipment.
  • Page 11: General Information

    General information...
  • Page 13: General

    Indicates a risk of flawed results and possible damage to the equipment. Device descrip- The Fronius Smart Meter TS is a bidirectional electricity meter which optimises self-con- tion sumption and records the household's load curve. In conjunction with the Fronius inverter, Fronius Datamanager and Fronius data interface, the Fronius Smart Meter TS provides a clear overview of a user's own power consumption.
  • Page 14: Positioning

    Positioning The Fronius Smart Meter TS can be installed in the following positions in the system: Positioning at the feed-in point: 0 0 1 Positioning at consumption point: 0 0 1 For use as a secondary meter to measure individual loads and producers, see chapter Multi-meter system on page 25.
  • Page 15: Installation

    Installation...
  • Page 17: Installation

    Start-up on page 31). Installation The Fronius Smart Meter TS can be mounted on a 35 mm DIN rail. The housing com- prises 3 modules according to DIN 43880. Protective circuit The Fronius Smart Meter TS is a hard-wired device and requires a disconnecting device (circuit breaker, switch or disconnector) and overcurrent‑protection (automatic‑circuit...
  • Page 18: Auxiliary Power Supply Cabling

    L1, L2 and L3. In rare cases, the neutral conductor has an overcurrent‑protection, which must interrupt both neutral and non-earthed cables concurrently. Auxiliary power IMPORTANT! supply cabling An auxiliary power supply is required to operate the Fronius Smart Meter TS. The fuse must match the dimensions of the conductors. L/N/+/- N/L/-/+ Cabling...
  • Page 19 1N1E 3-2E (1-3) 3-2E (1-3) 3-3E...
  • Page 20: Selection Criteria For Current Transformer

    3-2E 3-2 (1-3) 3N3E 3N3E Selection criteria General for current trans- Do not use current transformers with a voltage output. former Current transformers are directional. If they are mounted backwards or with swapped wires, the measured power will be negative. Primary current Maximum current per phase.
  • Page 21: Connecting The Current Transformers

    The Fronius Smart Meter TS needs 0.5 VA to carry out its measurements. Losses also occur on the outgoing and return leads. The power of the current converter must be greater than the sum total of the power of the Fronius Smart Meter TS and the leads. The higher the power, the better.
  • Page 22: Suitable Voltage Transformers

    * To avoid interference, the terminating resistor must be used (see chapter Terminating resistors on page 23). This is integrated in the Fronius Smart Meter TS and must be manufactured with a wire between M and T(T = termination). ATTENTION! ? More information on successful commissioning.
  • Page 23: Terminating Resistors - Explanation Of Symbols

    0 0 1 Terminating resistor R 120 Ohm is set with a wire jumper between M- and T. Modbus RTU slave e. g. Fronius Ohmpilot, Fronius Solar Battery, etc. Terminating resistor R 120 Ohm Terminating res- Due to interference, it is recommended that terminating resistors are used as illustrated istors below to ensure proper functioning.
  • Page 24: Multi-Meter System - Explanation Of Symbols

    OPTION 4 Manufacturer manual Manufacturer manual 0 0 1 max. 300 m * The terminating resistor for the Fronius Smart Meter TS is manufactured with a wire between M and T. Multi-meter sys- Grid tem - Explanation supplies the loads in the system if insufficient power is being generated of symbols by the solar modules or supplied by the battery.
  • Page 25: Multi-Meter System

    Terminating resistor R 120 Ohm Multi-meter sys- If several Fronius Smart Meter TS are installed, a separate address must be set for each (see Setting the address on the Fronius Smart Meter TS on page 28). The primary meter is always assigned address 1.
  • Page 26: Parameters Menu

    Only assign each Modbus address once. Terminating resistors must be positioned individually for each channel. For PV systems with inverters from the Fronius GEN24 and Fronius Tauro product series, the following must be observed: The primary meter and the battery must be connected to different channels.
  • Page 27: Setting The Transformation Ratio Of The Current And Voltage Transformers

    Screen Code Description Values MEASurE Measurement mode ** A: easy connection, measures all energy without taking the direction into account. B*: measures imported and exported energy separately. InStALL Connection check On: activated Off*: deactivated P int Average power calculation 1* - 30 interval (minutes) MOdE Display mode **...
  • Page 28: Setting The Address On The Fronius Smart Meter Ts

    1), 3) Ratio of voltage transformers (001.0 - 1000 Important! Changing the transformation ratios will reset the counters in the Fronius Smart Meter TS to 0. Transformation ratio in the current transformer x Transformation ratio of the voltage transformers = max. 1000...
  • Page 29 Press and hold "Enter" for 2 seconds. PASS Use "Up" or "Down" to access the P1 screen. Set password "2633" with "Up" and 2633 "Down" and confirm each individual value with "Enter". Use "Up" or "Down" to access the P14 screen.
  • Page 31: Start-Up

    Start-up...
  • Page 33: Fronius Snapinverter

    The service password must be entered in order to access the "Meter" menu item. Three-phase or single-phase Fronius Smart Meter TS can be used. In both cases, the selection is made under the "Fronius Smart Meter" item. The Fronius Datamanager auto- matically identifies the meter type.
  • Page 34: Configuring The Fronius Smart Meter Ts As A Secondary Meter

    Enter the name of the secondary meter in the "Name" input field. Enter the previously assigned address in the “Modbus address” input field. Add meter description. Click the button to save the settings. The Fronius Smart Meter TS is configured as a secondary meter.
  • Page 35: Fronius Gen24 Inverter

    The service password must be entered in order to access the "System configuration" menu item. Three-phase or single-phase Fronius Smart Meter TS can be used. In both cases, the selection is made under the "Components" menu area. The meter type is determined automatically.
  • Page 36: Configuring The Fronius Smart Meter Ts As The Primary Meter

    Access the "Components“ menu area. Click the "Add component" button. In the "Position" drop-down list, set the position of the meter (feed-in point or con- sumption point). For more information on the position of the Fronius Smart Meter TS, Positioning on page 14.
  • Page 37: Operation

    Operation Menu structure A graphic view of the menu structure can be found in the User Information that is sup- plied as standard.
  • Page 38: Technical Data

    Technical data Technical data Modbus transmission speed: 9600 baud Parity bit:none Software version: Fronius Datamanager 2.0 (from version 3.16.1 onwards) Fronius Symo Hybrid (from version 1.16.1 onwards) Measuring input Three-phase nominal voltage 400 - 480 V Operating range 320 - 552 V (-20% to +15%)
  • Page 39 Energy Response time after switch-on < 5 s (EN IEC 62053-21, EN IEC 62053-23) kCT x kVT Maximum display Resolution 1 - 9.9 9 9 9 9 9 9 . 9 9 kWh / kvarh 10 Wh / varh 10 - 99.9 9 9 9 9 9 9 9 .
  • Page 40: Fronius Manufacturer's Warranty

    0.05 mm² Recommended torque max. 0.4 Nm Fronius manufac- Detailed, country-specific warranty terms are available on the internet: turer's warranty www.fronius.com/solar/warranty To obtain the full warranty period for your newly installed Fronius inverter or storage sys- tem, please register at: www.solarweb.com.
  • Page 44 FRONIUS INTERNATIONAL GMBH Froniusstraße 1 A-4643 Pettenbach AUSTRIA contact@fronius.com www.fronius.com Under www.fronius.com/contact you will find the addresses of all Fronius Sales & Service Partners and locations.

Table of Contents