Modbus parti-
A maximum of 4 Modbus participants can be connected to the Modbus terminal.
cipants - Fronius
SnapInverter
IMPORTANT!
Only one primary meter, one battery and one Ohmpilot can be connected per in-
verter. Due to the high data transfer of the battery, the battery occupies 2 parti-
cipants.
Example:
Multi-meter sys-
If several Fronius Smart Meter TS are installed, a separate address must be set
tem - Fronius
for each (see
SnapINverter
The primary meter is always assigned address 1. All the other meters are
numbered consecutively with the address range from 2 to 14. Different Fronius
Smart Meter power categories can be used in combination.
IMPORTANT!
Max. Use 3 secondary meters in the system. To avoid interference, it is recom-
mended to install the terminating resistors according to chapter
terminating resistor
Location of the primary meter in the consumption branch. *Terminating resistor R 120 Ohm
24
Input
Battery
Setting the address on the Fronius Smart Meter TS
on page 21.
Quantity
Fronius
Primary
Ohmpilot
meter
1
1
1
1
Quantity
Secondary
meter
0
1
2
3
on page 31).