Design; Malfunctions - Optimum Optidrill B 34H Operating Manual

Table of Contents

Advertisement

Available languages

Available languages

5.6.1

Design

LCD display
Conversion
mm/inch
Value increase
Value decrease
ON / O,
switches the display on and resets the reading of the display to "0".
mm/in,
converts the measuring unit from millimetres to inches and vice versa.
OFF,
switches the display off.
,
performs a value increase.
,
performs a value decrease.
INFORMATION
Before inserting the new battery, wait about 30 seconds. Please make sure, that the contacts
are metallically bright and free from coverings which result from bleeding or gassing batteries.
Grip the new batteries only with plastic forceps, if possible not with the hand due to the forma-
tion of oxide and never with metal forceps in order to avoid a short circuit. In most cases the
round cell will be inserted into the digital display with the marking upside. After inserting the
round cell, the battery compartment has to be closed again.
5.6.2

Malfunctions

Malfunction
Flashing of the display
Screen doesn't refresh
No data visible
GB
B34H | B34HV
100
Abb.5-7: Digital display
Cause/
possible effects
Voltage too low
Disturbance in the circuit
No power supply
Battery voltage less than 1,55V
Translation of the original instructions
Off - switch
On - switch
On switch Zeroing
Battery bay
Solution
Change battery
Remove the battery, wait 30
seconds and reinsert the battery.
Clean battery contacts
Replace battery