Menu 7.8.3 - Setting The Solar Mode - RADEMACHER 1623 45 Operating And Assembly Manual

Electronic roller shutter belt winder rollotron comfort duofern
Table of Contents

Advertisement

17.2 Menu 7.8.2 - Set DuoFern mode
1.
Select and open menu
7.8.2 DuoFern mode.
2.
Select and confirm the
mode.
1 = DuoFern receiver
2 = DuoFern transmitter
3 = Local operation

17.3 Menu 7.8.3 - Setting the solar mode

This function enables you to determine how the RolloTron
Comfort DuoFern reacts to signals from a locally connected
light sensor or control commands from a central sun
shading controller (e.g. a DuoFern radio sun sensor).
The subsequent configuration of the automated solar
functions is correspondingly influenced by the selection
of the solar mode.
NOTE
Regardless of the set mode, all manual and automatic
control signals received via radio will be executed locally.
With one exception:
Control commands for the automated solar functions will
only be accepted if the solar mode [ 3 ] is activated (see
next chapter).
The following solar modes can be selected:
[ 1 ] = Local light sensor
[ 2 ] = Local light sensor and sunshine position
[ 3 ] = Central sun shading controller
EN