RADEMACHER RolloHomeControl Troll Standard 3650 03 12 Operating And Assembly Manual

Ultra-white, aluminium, 50mm switch range
Table of Contents

Advertisement

Quick Links

Troll Standard
EN
Operating and Assembly Manual for 50mm Switch Range
VBD 592-2 (09.13)
Item No:
3650 03 12 (ultra-white)
3650 03 22 (aluminium)

Advertisement

Table of Contents
loading

Summary of Contents for RADEMACHER RolloHomeControl Troll Standard 3650 03 12

  • Page 1 Troll Standard Operating and Assembly Manual for 50mm Switch Range Item No: 3650 03 12 (ultra-white) 3650 03 22 (aluminium) VBD 592-2 (09.13)
  • Page 2 Dear Customer, With your purchase of a Troll Standard, you have chosen a These instructions... quality product manufactured by RADEMACHER. Thank you for ...describe how to install, connect the electrical system and the trust you have placed in us. operate your Troll Standard.
  • Page 3: Table Of Contents

    Table of Contents 1. Scope of delivery / general view ......4 16. Initial commissioning with the help of the 20.3 Menu 9.6 - Configuration of 2. The key functions ..........5 installation wizard ..........21 blockage detection [ ] ......34 3. Display symbol legend .........6 17.
  • Page 4: Scope Of Delivery / General View

    1. Scope of delivery / general view [ 1 ] Operating unit Display Set key Menu key Up key SET/Stop key Set key Legend OK key 1. Operating unit (50 x 50) mm Down key 2. Frame 3. Installation housing 4. 1 x operating manual (not illustrated)
  • Page 5: The Key Functions

    2. The key functions The operating keys [ up / down ] The set keys, [ / ] ◆ Manual operation [ up / down ]. ◆ Selects the desired menu item. ◆ Setting the parameters (increase / decrease) / pressing and holding a key for an extended period causes the digits SET/Stop key, [ to change more quickly.
  • Page 6: Display Symbol Legend

    3. Display symbol legend [ MO ... SO ] Week days (MON...SUN) Time / setting parameters Information Switching programme [ SET ] Setting [ AUTO ] Automatic operation [ IST ] ACTUAL value Direction of travel - up / down Automatic mode off Timer periods Random function...
  • Page 7: Menu Overview

    4. Menu overview...
  • Page 8: Key To Symbols

    5. Key to symbols Risk of fatal electric shock. NOTE / IMPORTANT / CAUTION In this way, we wish to make you aware of the following content This symbol warns of danger when working on electrical in order to ensure optimal functionality. connections, components, etc.
  • Page 9: General Safety Information

    6. General safety information Danger due to electric shock when working on all Incorrect use leads to an increased STOP electrical systems. risk of injury. ◆ The electrical connection and all work on electrical ◆ Children may not be permitted to play with the Troll systems must only be carried out by a qualified electrician Standard.
  • Page 10: Proper Use

    7. Proper use Only use the Troll Standard for connecting and controlling a Operating conditions: tubular motor for Venetian blinds, slats or awnings. ◆ The tubular motor must be fitted with a mechanical or electronic end position switch. ◆ Only operate the Troll Standard in dry rooms. ◆...
  • Page 11: Brief Description

    9. Brief description The Troll Standard controller is designed for controlling roller Brief description of blockage detection function shutters, Venetian blinds, slats or awnings by connecting a The Troll Standard is able to monitor the torque of motors corresponding tubular motor. equipped with mechanical end point setting.
  • Page 12: Compatible Switch Ranges

    9.1 Compatible switch ranges. Manufacturer switch range NOTE BERKER Arsys / K1 / S1 ◆ It may be necessary to use an intermediate frame 50 x 50 * (DIN 49075), depending on the respective switch range used. BUSCH-JAEGER Busch-Duro 2000 Si / Reflex Si / alpha exclusive / alpha nea / solo / impuls * not included GIRA...
  • Page 13: Overview Of Features

    10. Overview of features ◆ Installation wizard for easy commissioning. ◆ Random function (random delay of 0 to 30 minutes) ◆ Configurable blockage detection for mechanical tubular motors ◆ Key lock ◆ Manual operation on site ◆ Memory function (easy acceptance of the current time as switching time) ◆...
  • Page 14: Important Information Prior To Electrical Installation And Mounting

    11. Important information prior to electrical installation and mounting Installation and electrical connection of the Troll Standard NOTE may only be undertaken with the supplied installation Installation housings for other variants of the Troll controller are housing [ 3 ]. not compatible.
  • Page 15 Blockage detection is only operational if a mechanical tubular A maximum of 3 tubular motors can be connected in parallel to the controller (e.g. RADEMACHER electronic tubular motors). motor is connected. To do so, please refer to the operating manual for the Function of inputs E1 / E2 corresponding tubular motor.
  • Page 16: Safety Instructions For Electrical Connection

    12. Safety instructions for electrical connection Danger due to electric shock when working on all Incorrect wiring may lead to short-circuits and destroy electrical systems. the device. ◆ The electrical connection and all work on electrical ◆ Follow the pin assignment detailed in the wiring diagram. systems must only be carried out by a qualified electrician ◆...
  • Page 17: Electrical Connection Of The Troll Standard

    13. Electrical connection of the Troll Standard Connecting the white set lead (SET) from RADEMACHER tubular motors * The white set lead (SET) from RADEMACHER tubular motors must be connected to the neutral terminal [ N ] to ensure trouble-free operation of the tubular motor.
  • Page 18: Assembly

    14. Assembly The Troll Standard is designed for flush-mounted installation. Installation procedure: For this, you require a 58 mm flush-mounted box. We Switch off the mains. recommend using a deep box. Make the electrical connection according to the wiring diagram (see page 17).
  • Page 19: Brief Description Of The Standard Display And Main Menu

    15. Brief description of the standard display and main menu The standard display (example) The main menu Menu number Functions / menus ◆ Displays the current day of the week and time. ◆ Enables display and selection of the individual functions and menus.
  • Page 20: Opening And Closing The Menus

    15.1 Opening and closing the menus (example: activating the random function) Call up the main Select the desired setting menu. and confirm with [ OK ]. By pressing the [ M ]-key in the standard Subsequently the main display. menu will be displayed Select the desired again.
  • Page 21: Initial Commissioning With The Help Of The Installation Wizard

    16. Initial commissioning with the help of the installation wizard An installation wizard is available in order to help you configure Set and confirm the the Troll Standard quickly and easily. The wizard automatically time. guides you through the configuration process for initial NOTE commissioning or after a software reset (see page 42).
  • Page 22 16. Initial commissioning with the help of the installation wizard Set and confirm the If necessary, you can NOTE opening time [ ]. subsequently select between At this point, the closing three switching time time is preconfigured as This opening time programmes from menu [9.5], the weekly switching applies to the entire...
  • Page 23: Manual Operation

    17. Manual operation Manual operation is possible from the standard display at any time and has priority over the programmed automatic functions. Example for manual control of a roller shutter Open the roller shutters. Briefly pressing the button causes the roller shutters to move to the upper end point.
  • Page 24: Memory Function - Accepting The Current Time As Switching Time

    18. Memory function - accepting the current time as switching time The memory function enables you to easily adapt the switching Accept the current times during the course of the year by allowing the current time time as the opening approx.
  • Page 25: Menu Overview / Main Menu

    19. Menu overview / main menu Standardised menu structure for Troll range Main menu A standardised, cross-variant menu structure has been developed Icon Menu Page for all Troll models, featuring an identical set of menu numbers for each of the menus. AUTO Automatic mode ......
  • Page 26: Brief Description

    19.1 [ AUTO ] Automatic mode; brief description Automatic mode on Automatic mode off Icon in standard display All of the activated automatic functions will be executed if the automatic mode is switched on. The corresponding icon is then ◆ All automatic functions are deactivated; only manual shown in the standard display.
  • Page 27: Auto ] Automatic Mode

    19.2 Menu 1- Automatic mode on / off Toggling directly to the standard display Switch on/off in menu 1 You can also directly toggle automatic mode on and off in the Call up the main menu. standard display. Select and open menu 1 [ AUTO ].
  • Page 28: Switching Times (Opening And Closing Times) [ / ]; Brief Description

    19.3 Switching times (opening and closing times) [ / ]; brief description You can configure various opening [ ] and closing times [ ] For this purpose, there are two switching time for the Troll Standard in order to open or close your roller shutters programmes available in menu 9.5 [ ] see page 33: at your preferred times.
  • Page 29: Menu 2 - Configuration Of Opening And Closing Times [ / ]

    19.4 Menu 2 - Configuration of opening and closing times [ / ]. Please check to see See menu [9.5], page 33 The following serves to describe the procedure for setting an opening and closing time [ / ] as a weekly switching time. whether the desired switching time programme is configured.
  • Page 30: Menu 6 - Configuring The Random Function

    19.5 Menu 6 - Configuring the random function [ The random function enables a random delay of the set timer Call up the main menu. periods ranging between 0 and 30 minutes. The random function is executed for: Select and open menu 6 ◆...
  • Page 31: Menu 9 - System Settings

    20. Menu 9 - System settings [ ]; brief description 9.8.1 This menu enables you to configure additional devices and sys- Automatic summer / winter tem settings to customise your Troll Standard to your individual changeover ......37 preferences. 9.8.2 Display contrast ....
  • Page 32: Menu 9.1 - Set Time And Date [ ]

    20.1 Menu 9.1 - Set time and date [ Select and open menu 9.1 Date Time and date. Setting order [ Day.Month ] Year Time NOTE Pressing the setting key for an extended period causes the numbers to progress more quickly.
  • Page 33: Select Menu 9.5 - Switching Time Programme

    20.2 Select Menu 9.5 - Switching time programme [ The number of opening and closing times that can be configured Select and open menu 9.5 depends on the desired switching programme selected in Switching time this menu. programme. There are two switching time programmes available: Select and confirm the [ 1 ] Weekly switching times (factory setting) desired switching time...
  • Page 34: Menu 9.6 - Configuration Of

    20.3 Menu 9.6 - Configuration of blockage detection [ ] The Troll Standard is able to monitor the torque of motors Select and open equipped with mechanical end point setting. This enables the menu 9.6 Blockage controller to switch off the motor in the event of overloading detection.
  • Page 35 20.3 Menu 9.6 - Configuring blockage detection [ ] Select and confirm the Set and confirm the suitable motor type. sensitivity level. Sensitivity: In order to do so, please 1 = low refer to the operating 6 = high manual for the respective tubular motor.
  • Page 36 20.3 Menu 9.6 - Configuring blockage detection [ ] ◆ It is possible that the motor will be switched off by the Activate / deactivate blockage detection system when moving out of the end reversing after points when using mechanical motors with high switching blockage detection.
  • Page 37: Menu 9.8.1 - Automatic Summer/Winter Changeover On/Off

    20.4 Menu 9.8.1 - Automatic summer/winter changeover on/off The Troll Standard features an automatic summer/winter Select and open menu changeover function. 9.8.1 Summer/winter changeover. NOTE If the controller is not being used in Germany, it may be necessary to switch off the automatic summer / winter clock Activate/deactivate change function.
  • Page 38: Menu 9.8.2 - Set Display Contrast

    20.5 Menu 9.8.2 - Set display contrast Select and open Set and confirm the menu 9.8.2 Display desired display contrast. contrast. 1 = low contrast 10 = high contrast 20.6 Menu 9.8.4 - Set clock mode This menu enables you to configure the time base for the Set and confirm the clock internal clock (depending on the local power supply).
  • Page 39: Menu 9.8.5 - Switch Key Lock On/Off

    20.7 Menu 9.8.5 - Switch key lock on/off You can activate the key lock to protect against unintentional Press and hold the input. [ SET/Stop ] key for approx. four seconds in order to Automatic activation after approx. two minutes. 4 sec.
  • Page 40: Menu 9.8.7 - Switch Reversal Of Rotation Direction On/Off

    20.8 Menu 9.8.7 - Switch reversal of rotation direction on/off It is not necessary to re-wire the motor if the direction of rotation Select and open menu for the connected motor is wrong ([ Up ] key moves the roller 9.8.7 Reversal of shutters downwards and [ Down ] key moves the roller shutters rotation direction...
  • Page 41: Menu 9.8.0 - Display Software Version

    20.9 Menu 9.8.0 - Display software version This menu enables the current software version for the Troll Select and open menu Standard to be displayed. 9.8.0 Software version. Subsequently the current software version will be displayed. Pressing once more causes the device type to be displayed.
  • Page 42: Software Reset (Restore Factory Settings)

    21. Software reset (restore factory settings). If necessary, you can Next, the device type erase all of your settings (S = standard) and and return the Troll software version will Standard system to its be displayed for a few original factory settings. seconds.
  • Page 43: Hardware Reset

    22. Hardware reset A hardware reset can be carried out in the event that the Troll Standard fails to react to commands. To do so, pull the control unit [ 1 ] our of the installation housing [ 3 ]. The centre section on rear of the control unit [ 1 ] contains two contacts which should be carefully bridged for a few seconds, for example, with the help of a flat-head screwdriver.
  • Page 44: Dismantling

    23. Dismantling During both installation and dismounting of the Troll Procedure for dismantling: Standard, there is a risk of fatal electric shocks. Switch off the mains. Follow the safety instructions for electrical connection Secure the connector against reconnection and check that the on page 16.
  • Page 45: Ce Mark And Ec Conformity

    European and national directives: 2006/95/EC Low-voltage directive 2004/108 EC EMC directive Conformity has been verified. The corresponding declarations and documentation are available on file at the manufacturer’s premises. RADEMACHER Geräte-Elektronik GmbH Buschkamp 7 46414 Rhede (Germany)
  • Page 46: Technical Specifications And Factory Settings

    25. Technical specifications and factory settings External dimensions control unit [ 1 ]: 50 x 50 mm x 12 Factory settings: (according to DIN 49075) Automatic: Colour: ultra-white / aluminium Timer periods: Nominal voltage: 230 V / 50 Hz Up time: 7:00 hours Max.
  • Page 47: Warranty Conditions

    26. Warranty conditions RADEMACHER Geräte-Elektronik GmbH provides a 24-month warranty RADEMACHER shall remedy any defects that fall under the warranty for new systems that have been installed in compliance with the period free of charge, either by repairing or replacing the affected installation instructions.
  • Page 48 RADEMACHER Geräte-Elektronik GmbH Buschkamp 7 46414 Rhede (Germany) info@rademacher.de www.rademacher.de Service: Hotline 01807 933-171* Fax +49 2872 933-253 service@rademacher.de * 30 seconds free of charge, subsequently 14 cents / minute from German fixed line networks and max. 42 cents / minute from German cellular networks.

This manual is also suitable for:

Rollohomecontrol troll standard 3650 03 22

Table of Contents