3.8 Power Measurement
The S1132 signal generator can perform power measurement by using SUP60 USB power sensor.
Operation steps:
1. Instrument connection
Use the USB cable to connect the power sensor to the USB port of the signal generator, then connect the signal
input port of the power sensor to the RF signal output port of the signal generator.
2. Parameter setting
(1) Reset the signal generator
— Press【Preset】
(2) Parameter setting
— Press【FREQ】
— Press【AMPT】
— Press【RF1】
— Press【AuxFctn】
— Select [USB Power]
— Select [State] -- "On"
— Select [Channel Freq], input 1 GHz, same as the output frequency of signal generator
button
button, input 1 GHz
button, input -10 dBm
button, make the【RF1】button backlight bright
button
Tel: 886. 909 602 109
36
Email: sales@salukitec.com
www.salukitec.com