Available languages

Installation
Fig. 1: Machine connection points
[
]
[
[
]
[
]
A
[
]
A
A
B
Drain pipe ⌀ 30 mm
[UX50 and
A
UX50 Lite: models
without
drain
pump]
Drain pipe ⌀ 30 mm
[UX50 and
A'
UX50 Lite: models
with
drain pump]
Preparation for installation
1)
Check that the installation area is flat and stable.
2)
Check that the water line has a ¾" GAS shut-off valve at the end
closest to the machine.
3)
Check that the dynamic pressure of the machine feed water is
within the following range of values:
Dynamic water pres-
Minimum value
sure
C Models
0.7 bar (70 kPa)
D and V models
2.5 bar (250 kPa)
Other models
2 bar (200 kPa)
If the water pressure is higher than the maximum indicated,
install a pressure regulator to set the pressure between 2.5
and 4 bar (250 and 400 kPa).
If the water pressure is below the minimum value, install a
back-up valve.
User's manual — 2900455/0
UX 40
[UX 40/S]
[UX 40/S]
]
B
C
UX 50
UX 50 Lite
A'
C
B
UX 100 Lite
UX 120
C
B Water inlet ¾" GAS
C Connection cable
Maximum value
4 bar (400 kPa)
4 bar (400 kPa)
4 bar (400 kPa)
4)
Check the following values of the feed water flow rate:
Water flow rate
Minimum value
C Models
Other models
5)
[Models without drain pump]
outer diameter of 30 mm to the drain line [Fig. 1/A]. For the
maximum drain height, observe the following values:
Drain height
Models with drain pump (B)
Dome models without drain pump
Other models
2.3
Unpacking
⚠ W a rn in g
Risk of trapping hands
There is a high risk of trapping your hands if you lift the ma-
chine onto the base and place it on the ground.
– To move the machine from one place to another, hold the
machine from the sides.
1)
Remove the packaging that protects the machine.
2)
Lower the machine from the pallet on which it is mounted.
2.4
Assembly
⚠ W a rn in g
Risk of serious accidents if the machine cannot be
disconnected or turned off
– When installing the machine, make sure the operator will be able
to reach the switch and plug without difficulty.
Notice
Risk of water leakage
– Before installation, turn off the water stopcock.
1)
Screw the legs to the base of the machine.
2)
Adjust the height of the legs so that the machine is stable and
level with the ground.
3)
Place the machine at the installation site.
4)
Check that the tap water pressure is within the parameters
specified in the previous chapter (use of the pressure gauge).
Notice
Risk of hose clogging and/or choking
– Avoid making reductions with the hose when installing.
5)
Connect the water outlet hose to the drain point.
6)
Connect the water supply hose to the mains water point.
7 L/min
15 L/min
Connect the drain pipe with an
Maximum value
1,000 mm
500 mm
90 mm
EN
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ux-50Ux-50 liteUx-100 liteUx-120

Table of Contents