Stanley BRANDON 80K Installation And Commissioning Instructions

Stanley BRANDON 80K Installation And Commissioning Instructions

Gas fired cooker

Advertisement

Quick Links

BRANDON
80K/100K GAS FIRED COOKER
TO BE INSTALLED BY A TRAINED COMPETENT PERSON
Installation and Commissioning Instructions
THIS MANUAL IS TO BE LEFT WITH END USER

Advertisement

Table of Contents
loading

Summary of Contents for Stanley BRANDON 80K

  • Page 1 BRANDON 80K/100K GAS FIRED COOKER TO BE INSTALLED BY A TRAINED COMPETENT PERSON Installation and Commissioning Instructions THIS MANUAL IS TO BE LEFT WITH END USER...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS PAGE NO. Introduction ............2 Specification .
  • Page 3: Introduction

    S.I. 101 of 1992 (as amended). S.I. 150 of 1995 (as amended). IMPORTANT NOTICE: Any alteration to this appliance that is not approved in writing by Waterford Stanley, will render the guarantee void. The Installation must comply with the following: The Building Regulations: Part J England &...
  • Page 4: Specification

    U.K.: ALL GAS APPLIANCES MUST BY LAW BE IRELAND: APPLIANCES MUST INSTALLED BY A COMPETENT PERSON, ONLY INSTALLED COMPETENT PERSON USE A C.O.R.G .I REGISTERED ENGINEER. OUTLINED IN I.S. 813. APPLIANCE MUST CONNECTED FULLY PUMPED SYSTEM. The manufacturers reserve the right to make alterations to design, materials or construction for manufacturing or other reasons subsequent to publication. Specification NOTE: Dimensions stated below may be subject...
  • Page 5: Technical Data

    TECHNICAL DATA FUELS: 2nd Family, Natural Gas PRODUCT IDENTIFICATION: 63AR5080 COUNTRY OF DESIGNATION: I.E., G .B. GAS TYPES: N.G .: H, G20, 20 mbar (I.E., G .B.) MAINS CURRENT : 230V - 240V, 50 Hz, A.C. SUPPLY FUSE RATING: 5 Amp. IONISATION CURRENT : Minimum of 7µa I.P .
  • Page 6: Schematic

    This appliance has been tested and approved in accordance with Gas Appliance Directive (90/396/EEC), the Voltage Directive (72/23/EEC) Electromagnetic Compatibility Directive (89/336/EEC) amended. SCHEMATIC Fig 1. Platerack (to order) Splashback (to order) Hotplate Covers 150mm (6”) 90° Bend Bend Cleaning Plate T owel Rail Firedoor Burner Door...
  • Page 7: Location

    Stanley leaving a 5mm gap (see fig. 2 & 3). Likewise the base of When...
  • Page 8: Chimney's

    150mm (6”) Diameter Flue Liner Do not connect to a flue serving another appliance. Always ensure that the connection is to a chimney of Fig.6 the same size - never connect to one of smaller Vermiculite dimensions. Flues wholly constructed of single skin a Comparable Material pipe...
  • Page 9: Sealing

    Fig.8 Fig.8a Flue greater than 150mm (6”) Diameter Fig. 7 Approved Flue T erminal Refer to Flue Assembly Instruction sheets. Clay Liner Fig.9 Vermiculite Filler or comparable material Flexible Flue Liner 150mm (6”) Sealing & Clamping Plate Seal Flue Connector FLUE HEIGHT flue must...
  • Page 10: Connections

    (Removal debris should facilitated STANLEY CAST IRON PIPES AND BENDS ARE provision of an access door). The void should have HIGHLY RECOMMENDED FOR INTERIOR USE. a depth of not less than 250mm (10”) below the appliance connection.
  • Page 11: Factory Made Insulated Chimneys

    part of any flue terminal. These air vents must also Parts 1, 2 & 3 should be used. The liner should be satisfactorily fire proofed Building secured at the top and bottom by using closure/ Regulations. clamping plate firmly sealed and secured and an approved low resistance terminal used at the top.
  • Page 12: Down Draughts

    DOWN DRAUGHTS Air inlets traversing cavity walls should include a continuous duct across the cavity. The duct However well designed, constructed should be installed in such a manner as not to positioned, the satisfactory performance of the flue impair the weather resistance of the cavity. can be adversely affected by down draught caused Joints between...
  • Page 13: Gas Pipe Size

    existing meter have it checked to ensure that the GAS PIPES AND FITTINGS meter is capable of dealing with the total rate of gas Materials used for installation work should be fire supply needed (see T echnical Data). resistant and gas tight and should conform to the following or their equivalent.
  • Page 14: Draining

    motorised valves, room thermostats, DRAINING radiator thermostatic valves, domestic water Key-operated drain taps 2879 should controllers, etc, greatly enhance heating provided in accessible positions in all low parts of system and we recommend their use. the system. However, it should be noted that there Only approved competent...
  • Page 15: General Maintenance

    Authorised Stanley Service unnecessary break-downs. Engineer at least once a year. recommend that evaluate overall NOTE: As the valve and the venturi come preset, insulation in your house, i.e.
  • Page 16 SEALED SYSTEM (WITH PUMP ON FLOW) Fig. 21 OPEN SYSTEM (WITH PUMP ON FLOW) Fig.22...
  • Page 17 INTERLINK SYSTEM Fig.23 PROVISION FOR FILLING SEALED SYSTEM S PLAN SYSTEM Fig.24 Fig.25 TEMPORARY HOSE (Must be disconnected after filling)
  • Page 20: Wiring Diagram S Plan

    GREY GREY...
  • Page 21: Zone Heating Systems

    4 ZONE HEATING SYSTEM Under circumstances other supply 4 ZONE HEATING SYSTEM sources be connected directly to the cooker. When connecting the a Brandon cooker to a 4 - zoned heating system (i.e. separate time switches thermostats domestic water four central heating zones), the domestic hot water and zone must...
  • Page 23: Commissioning Checks

    COMMISSIONING CHECKS Check all items of packaging are removed from 19. Check that interstat connection been ovens and the shelves are properly fitted. wired directly to a motorised valve. This is done by turning off room thermostats, time switches Check that electrical wiring is correct. and temporarily linking terminals 6 &...
  • Page 24: Commissioning Of Burners

    COMMISSIONING OF BURNERS Both burners used in the Brandon Cooker are fully Ionisation Current pre-mixed burners, thus allowing very silent ionisation current each burner must operation excellent combustion. burner measured. This is done by removing the ionisation controls are fully independent for each burner. lead from control...
  • Page 25: Burner Fault Finding Sequence

    Burner Fault Finding Sequence Starting point, call for heat but no main burner ignition Ignition board S4565AD Call heat from timer thermostat. Check for 230V ac NOTE to the fan motor. Is the fan running? When working correctly the gas valve will not pass gas unless the fan is running.
  • Page 26: 100K Boiler Burner Exploded View

    100K BOILER BURNER EXPLODED VIEW...
  • Page 27: K Boiler Burner Exploded View

    80K BOILER BURNER EXPLODED VIEW...
  • Page 28: 100K/80K Cooker Burner Exploded View

    100K/80K COOKER BURNER EXPLODED VIEW...
  • Page 29: Burner Parts List

    BURNER tech Burner Parts List 100K Boiler Burner - DESCRIPTION PART NO. BOM CODE PART NO. BOM CODE Burner Head 51005 D00134AXX 51005 D00134AXX Boiler Mounting Plate Gasket 88014 D00135AXX 88014 D00135AXX Burner Head Gasket 88018 D00136AXX 88018 D00136AXX Boiler Mounting Plate 71007 D00137AXX 71007...
  • Page 30 Waterford Stanley Bilberry, Waterford, Ireland. T elephone: (051) 302300 Facsimile: (051) 302375 N00351AXX Rev 001 DP 050729...

This manual is also suitable for:

Brandon 100k

Table of Contents